POSSIBLE APPLICATIONS
- Marine and Offshore structural steel
- Industrial Floor Coatings
- Storage tank protection
- Industrial structural steel
- Non-ferrous substrate as primer
- As penetrating primer for concrete protection
Air Temperature |
5-50°C |
Substrate Temperature |
5-55°C |
Relative Humidity |
50% minimum, 90% maximum |
Surface temperature shall always be at least 3°C above
Dew Point. Do
not expose the coated articles where there are chances of
condensation
on the surface. |
Surface Preparation
Aqua ST is highly flexible coating in terms of surface preparation
requirements. Surface preparation may differ according to the
final exposure or application of Aqua ST. Refer to Flosil-BET for
recommendation on required surface preparation
Mixing
Aqua ST is supplied in 2 parts, a liquid binder (Part A) and a
liquid binder (Part B). Always mix liquid (Part B) into the liquid
(Part A) while stirring. 75-100 RPM mixer is recommended.
Thinning
Aqua T01 – 10 - 20 %
Airless Spray
Recommended,0.43-0.53mm at 3500 - 4000 psi tip pressure.
Conventional Spray
Recommended. Do not exceed spray pressure than 4 Kg/Sq.Cm
Brush / Roller
Recommended
- Standard Packing
Size = 4 L (Mix Paint)
- Larger pack
sizes of 16 L & 20L available on request.
- Shelf Life: 24
months* from the date of manufacturing
*Material to be stored in sealed and unopened containers in closed shelter.